If the generator is stored outdoors, unprotected from the weather, check all of the electrical components on the control panel before each use. Moisture or ice can cause a malfunction or short circuit in electrical components that could result in electrocution.
The exhaust system gets hot enough to ignite some materials. Keep the generator at least 3 feet 1 meter away from buildings. Do not enclose the generator in any structure. Keep flammable materials away from the generator. The muffler becomes very hot during operation and remains hot for a while after stopping the engine.
Be careful not to touch the muffler while it is hot. Let the engine cool before storing the generator indoors. Gasoline is extremely flammable, and gasoline vapor can explode. Allow the engine to cool if the generator has been in operation.
Refuel only outdoors in a well-ventilated area with the engine off. Do not overfill the fuel tank. Never smoke near gasoline, and keep other flames and sparks away. Always store gasoline in an approved container. Make sure that any spilled fuel has been wiped up before starting the engine. These labels warn you of potential hazards that can cause serious injury. Read them carefully. If a label comes off or becomes hard to read, contact your Honda generator dealer for a replacement. Use the illustrations on these pages to locate and identify the most frequently used controls.
The engine switch controls the ignition system, and it operates the electric starter. Used when the battery voltage is too low to turn the starter motor. Pulling the starter grip operates the recoil starter to crank the engine. Do not allow the starter grip to snap back against the generator. Return it gently to prevent damage to the starter. Do not let the starter rope rub against the generator body, or the rope will wear out prematurely.
Be careful not to hit your hand against the handle when pulling the starter grip. The most power will be available at the 30A V locking plug receptacle. Auto Throttle System. The Auto Throttle system automatically reduces engine speed when all loads are turned off or disconnected. When appliances are turned on or reconnected, the engine returns to the rated speed. AUTO: Recommended to minimize fuel consumption and further reduce noise levels when no load is applied to the generator.
Recommended to minimize warm-up time when the. The AC circuit breaker will automatically switch OFF if there is a short circuit or a significant overload at the receptacles. The AC circuit protectors will automatically switch OFF if there is a short circuit or a significant overload of the generator at each receptacle.
If an AC circuit protector switches OFF automatically, check that the appliance is working properly and does not exceed the rated load capacity of the circuit before resetting the AC circuit protector ON. The terminals are colored red to identify the positive terminal and black to identify the negative terminal. The battery must be connected to the generator DC terminals with the proper polarity battery positive to generator red terminal and battery negative to the generator black terminal.
The DC circuit protector automatically shuts off the DC battery charging circuit when the DC charging circuit is overloaded, when there is a problem with the battery, or when the connections between the battery and the generator are improper. However, the DC circuit protector does not prevent overcharging. The foldable handle is intended for ease of transportation and should be folded when the generator is stationary.
Do not rest objects on the extended handle. Press handle lock lever downward. Oil Alert System. The Oil Alert system is designed to prevent engine damage caused by an insufficient amount of oil in the crankcase. Before the oil level in the crankcase can fall below a safe limit, the Oil Alert system will automatically stop the engine the engine switch will remain in the ON position.
If the engine stops and will not restart, check the engine oil level see page 43 before troubleshooting in other areas. During operation, the engine will automatically stop if there is not enough oil in the tank. Moreover, if the generator is on a slope, the oil alert function may operate and stop the engine. To protect the engine from exceeding the engine load, the engine will automatically stop if the engine speed becomes abnormal.
The engine will automatically stop during generation when it detects abnormal voltage. If the engine stops, make sure the oil level is correct. Wait a few minutes, and then try to restart the engine. When starting and warming up the engine, you do not need to operate the choke lever unless the engine is hard to start using the normal starting procedure. This generator is equipped with an intelligent, automatic voltage regulator.
The iAVR provides power in excess of the maximum rating for up to ten seconds to start appliances that require high startup current. The fuel gauge is a mechanical device that measures the fuel level in the tank. The red indicator in the window will reference the level in relation to full or empty.
To provide increased operating time, start with a full tank before beginning operation. Check the fuel level with the generator on a level surface. Always refuel with the engine OFF and cool. Page High Altitude Operation High Altitude Operation At high altitude, the standard carburetor air-fuel mixture will be excessively rich. Performance will decrease, and fuel consumption will increase.
High altitude performance can be improved by installing a smaller diameter main fuel jet in the carburetor and readjusting the pilot screw. If you always operate the engine at altitudes higher than 6, feet above sea level, have an authorized Honda generator dealer perform this carburetor modification.
Non-detergent the engine and are not recommended. Honda 4-stroke equivalent Page Fuel Recommendation Fuel Recommendation 1. Check the fuel level gauge. Refill the tank if the fuel level is low. Do not fill above the shoulder of the fuel strainer. Gasoline is extremely flammable and is explosive under certain conditions. Refuel in a well-ventilated smoke or allow flames or sparks in the area where the engine is refueled or where gasoline is stored.
This is no cause for concern. If spark knock or pinging occurs at a steady engine speed, under normal load, change brands of gasoline. If spark knock or pinging persists, see an authorized Honda generator dealer.
Page Starting The Engine 1. The generator may be hard to start if a load is connected. Turn the fuel valve to the ON position. The automatic choke will be closed if the engine is cold.
If you want to operate the choke manually, position. To stop the engine in an emergency, turn the engine switch to the OFF position. In normal use: 1. Disconnect DC battery charging cables.
Page Maintenance Periodic maintenance and adjustment is necessary to keep the generator in good operating condition. Perform the service and inspection at the intervals shown in the Maintenance schedule below.
Exhaust Shut off the engine before performing any maintenance. Page Tool Kit Tool kit The tools supplied with the generator will help you to perform the owner maintenance procedures listed on the following page. Always keep this tool kit with the generator.
Page Engine Oil Change Engine oil change Drain the oil while the engine is warm to assure rapid and complete draining. Remove the drain plug and sealing washer, oil filler cap, and drain the oil. Install the drain plug and sealing washer. Tighten the plug securely. Page Air Cleaner Service Air cleaner service A dirty air cleaner will restrict air flow to the carburetor. To prevent carburetor malfunction, service the air cleaner regularly. Service more frequently when operating the generator in extremely dusty areas.
Using gasoline or flammable solvent to clean the filter element can cause a fire or explosion. Page Fuel Sediment Cup Fuel Sediment Cup Cleaning The sediment cup prevents dirt or water which may be in the fuel tank from entering the carburetor. Turn the fuel valve to the OFF position.
Add To Cart. Close Quick Shop Error. Northern Safety. Check Order Status Go. Live Help. Send us a message. Frequently Asked Questions. More ways to contact us. Your Shopping Cart. Your shopping cart is empty. Remote Control Kit Remote Control Box Hanger Kit Honda generators are designed for use with electrical equipment that has suitable power requirements. Other uses can result in injury to the operator or damage to the generator and other property.
Most injuries or property damage can be prevented if you follow all instructions in this manual and on the generator. The most common hazards are discussed below, along with the best way to protect yourself and others. Do not let children operate the generator without parental supervision. A generator's exhaust contains toxic carbon monoxide, which you cannot see or smell. To avoid carbon monoxide poisoning, follow these instructions when operating a generator:. Early symptoms of carbon monoxide exposure include headache, fatigue, shortness of breath, nausea, and dizziness.
Continued exposure to carbon monoxide can cause loss of muscular coordination, loss of consciousness, and then death. To alert you to potentially dangerous levels of carbon monoxide coming from a generator operating outside, or from other sources, install battery operated carbon monoxide alarms or plug-in carbon monoxide alarms with battery back-up on every level of the home and outside sleeping areas in accordance with the manufacturer's instructions.
Keep the generator dry. Moisture or ice can cause a malfunction or short circuit in electrical components that could result in electrocution. Be careful not to touch the muffler while it is hot. Let the engine cool before storing the generator indoors. Gasoline is extremely flammable, and gasoline vapor can explode. Do not refuel during operation. Refuel only outdoors in a well-ventilated area and on a level surface.
Never smoke near gasoline, and keep other flames and sparks away. Do not overfill the fuel tank. These labels warn you of potential hazards that can cause serious injury. Read them carefully. If a label comes off or becomes hard to read, contact your Honda generator dealer for a replacement. Use the illustrations on these pages to locate and identify the most frequently used controls. The engine switch controls the ignition system, and it operates the electric starter.
Used when the battery voltage is too low to turn the starter motor. Pulling the starter grip operates the recoil starter to crank the engine. Return it gently to prevent damage to the starter. Direction to pull. The most power will be available at the 30A V locking plug receptacle. When appliances are turned on or reconnected, the engine returns to the rated speed. AUTO: Recommended to minimize fuel consumption and further reduce noise levels when no load is applied to the generator.
Recommended to minimize warm-up time when the generator is started and when starting a load with large start-up power requirements. The AC circuit breaker will automatically switch OFF if there is a short circuit or a significant overload at the receptacles. The AC circuit protectors will automatically switch OFF if there is a short circuit or a significant overload of the generator at each receptacle.
If an AC circuit protector switches OFF automatically, check that the appliance is working properly and does not exceed the rated load capacity of the circuit before resetting the AC circuit protector ON.
An example of ground-fault current is the current that would flow through a person who is using an appliance with faulty insulation and, at the same time, is in contact with an electrical ground such as a plumbing fixture, wet floor, or earth. The GFCI will protect against current flowing through that person. GFCIs can be expected to interrupt power supply if there are ground faults or stray current imposed on the wiring by other electrical devices, wiring, or equipment.
Due to the risk of a power interruption, this generator is not recommended for powering medical or life support equipment. The battery must be connected to the generator DC terminals with the proper polarity battery positive to generator red terminal and battery negative to the generator black terminal.
The DC circuit protector automatically shuts off the DC battery charging circuit when the DC charging circuit is overloaded, when there is a problem with the battery, or when the connections between the battery and the generator are improper. However, the DC circuit protector does not prevent overcharging. The foldable handle is intended for ease of transportation and should be folded when the generator is stationary.
Do not rest objects on the extended handle. Press handle lock lever downward. The Oil Alert system is designed to prevent engine damage caused by an insufficient amount of oil in the crankcase. Before the oil level in the crankcase can fall below a safe limit, the Oil Alert system will automatically stop the engine the engine switch will remain in the ON position. If the engine stops and will not restart, check the engine oil level see page 47 before troubleshooting in other areas.
During operation, the engine will automatically stop if there is not enough oil in the tank. Moreover, if the generator is on a slope, the oil alert function may operate and stop the engine. To protect the engine from exceeding the engine load, the engine will automatically stop if the engine speed becomes abnormal.
The engine will automatically stop during generation when it detects abnormal voltage.